Updates Delay (LogiX node)
Updates Delay | ||
---|---|---|
![]() | ||
Inputs | ||
Impulse | Trigger | |
Int | Updates | |
Outputs | ||
Impulse | Impulse | |
Impulse | OnTrigger |
The Updates Delay node is used to fire an impulse from Impulse
after a number of frame updates greater than or equal to Updates
have completed following an impulse received at Trigger
.
Usage
The Updates
input sets the number of frame updates which must complete before the delayed impulse is fired from Impulse
. The default value is 1.
The OnTrigger
output fires an impulse immediately after an impulse is received at Trigger
. This continues the impulse chain which arrived at Trigger
.
The delayed impulses do not continue the impulse chain which arrived at Trigger
and any temporary values present will have been lost - if a temporary value must be stored until the delayed impulse is fired use Updates Delay With Value. Each impulse which arrives at Trigger
sets up a separate delayed impulse and multiple can be queued at once with different delay durations.